establishment of a state-of-the-art Irradiation Center
Design, construction & turnkey project execution
Installation & commissioning of 500kCi Co-60 gamma irradiation system
Integrated conveyor irradiator with complete accessories
Comprehensive testing & performance validation
Fully compliant with international safety and quality standards
Supply, installation & commissioning of an advanced TLD reader
Accurate thermoluminescent dosimetry measurement
User-friendly operation with high precision
Compatible with various TLD chips & cards
Ensures reliable radiation monitoring and analysis
Supply, installation & commissioning of a new heat exchanger
Integrated motor supply & installation
Complete civil, piping & electrical works
System alignment & connection with existing setup
Performance testing & quality assurance
Turnkey solution for efficient heat exchange replacement
Supply, installation, testing & commissioning of draft-type cooling tower (Capacity: 680 RT)
Integrated chemical dosing system for water treatment
Comprehensive civil construction, piping & electrical works
Spare motor supply, installation & alignment
Complete system integration with existing infrastructure
Performance testing, quality assurance & commissioning
Installed at Centre for Research Reactor, AERE, Savar
Comprehensive radiation protection accessories for hot labs
Lead apron and lead goggles for personal safety
L-block tabletop shield for efficient handling
High-density lead bricks for flexible shielding
Syringe carrier and syringe shield for safe radiopharmaceutical handling
Lead pot for secure isotope storage
Mobile lead barrier for enhanced radiation protection
Gamma Counter with 5 & 10 detector options (through-hole type)
12-bit ADC with 4096 channels
Low background: I-125 & Co57 < 100
High efficiency: I-125 > 75%, Cs-137 > 26%
High resolution: I-129 < 28%, I-125 < 30%, Co57 < 17%
Large deck capacity: GAMMA-10 (540 tubes), GAMMA-5 (300 tubes)
Adjustable high voltage: 650V–800V (default 720V)
RF-ID system (1024 Bit TF Tag)
Dual power options: 220V & 110V
Compact dimension (mm)
X-ray calibration unit for Diagnostic, CT, Radiography & Mammography
Complete lab design and setup
Installation, commissioning & testing
Training
Dual-source neutron calibrator (Am/Be or Pu/Be, Cf)
Bonner Sphere neutron spectrum measurement
ISO & IAEA standards compliant
Complete lab design and installation
Training and full commissioning
High-Activity Facility: Purpose-built for handling and housing a 350,000 Curie (350 kCi) Cobalt-60 source, ensuring safe operation at high radiation levels.
Advanced Source Shielding: Incorporation of **multi-layered radiation shielding** (heavy concrete, lead, and steel as required) designed to comply with international safety standards.
Specialized Building Design: Customized structural layout including source storage pools, irradiation chambers, control rooms, and auxiliary facilities for seamless operations.
Safety & Compliance: Engineered to meet IAEA guidelines, AERB/IAEA/NRC safety codes, and other applicable regulatory requirements.
Automated Handling Systems: Provision for mechanized source movement and control systems to minimize manual handling and enhance operational safety.
Environmental & Occupational Safety: Incorporation of ventilation, monitoring, and shielding strategies to protect both the environment and personnel.
Durable Civil Structure: Robust reinforced concrete construction with enhanced seismic resistance and long-term durability.
Supporting Infrastructure: Includes utilities, backup power systems, security systems, and monitoring instrumentation for uninterrupted functioning.
Future-Ready Design: Flexible architecture enabling future expansion and source capacity upgrades as per operational requirements.